This site is intended for healthcare professionals outside the United States of America. By continuing to use this site you are confirming that that you are a healthcare professional based outside the USA

World’s longest lasting
ICD & CRT-D range1,2,3,4

World’s longest
projected longevity1,2,3,4

Longevity is based on real-life
pacing conditions.5

Longevity

VR

14.3 years

DR

13.1 years

CRT-D

10.9 years

SonR CRT-D

10 years

Extended Longevity.
Backed by Warranty.6

Warranty applies regardless of the
pacing conditions and therapy frequency.6

Warranty

VR

11 years

DR

9 years

CRT-D

7 years

SonR CRT-D

6 years

Platinium vs. Enduralife™

Platinium outlasts Enduralife™
technology by 12% under comparable settings.4

Pacing Mode: DDD
Rate: 60bpm
Amplitude: 2.5V @ 0.4ms (RA, RV)
Counters: 15% AP, 15% VP
Impedance: 500Ω
EGM storage: ON (3 channels)
Sensors: ON (G+MV for Resonate™ and G only for Platinium)
Shocks: 2 max shocks/year
Remote monitoring: ON, with daily alert checks, quarterly remote follow-ups
RF telemetry: 1 hour at implant, 40min/year
for in-clinic FU checks

+12%

Longevity

DR

Boston Scientific

RESONATE EL

DR

Breakthrough Technology

That stands the test of time.

body
capacitors

Capacitors

0

Energy wasted

Capacitors

Reforming-free capacitors

battery

Battery

20%

Improved capacity*

Battery

Total battery capacity: 2.19Ah

Platinium has a built in security margin of a minimum of 10 months between RRT and EOL even under demanding conditions.7
Once RRT is reached, Platinium SonR CRT-D programmed with 100% atrial and BiV pacing will still have a minimum of 10 months remaining battery life and will be able to deliver 11 shocks.

*Versus previous ICD & CRT-D generation

electronics

Electronics

40%

Reduced intrinsic consumption*

Electronics

Intrinsic consumption: 6.2μA**

*Versus previous ICD & CRT-D generation
**indicated at 60bpm (μA on Vbat)

Simulate Platinium
Longevity

Simulate the longevity of Platinium
devices with your own settings.

bg_shape_1

Avoid Risky
Replacements

Sooner or later, the issue of replacement will arise and with it risks of serious complications.

Reduce Healthcare Costs

Healthcare Cost Savings.

Device longevity has an important economic impact.
Extended longevity significantly decreases the cost of therapy.

Up to

21%

Savings

ICD

From 9
to 14 years
longevity

Up to

26%

Savings

CRT-D

From 6
to 10 years
longevity

Expected average savings per patient implanted over a 15-year time period.8

br_shape_2

Hear it from the experts

References

1.

Medtronic - VISIA™ AF MRI VR SureScan™ DVFB1D4 Device manual M961177A001 B 2015-07-02. EVERA™ XT DR DDBB1D4 Device manual M946302A001 F 2014-03-11. CLARIA™ MRI QUAD CRT-D SureScan™ DTMA2QQ Device manual M956980A001 B 2017-07-17.

2.

Biotronik - ILIVIA™ 7 VR-T, VR-T DX, DR-T, HF-T, HF-T QP (ProMRI®) Technical Manual 417641 Revision: D (2016-08-09).

3.

Saint Jude Medical - Bradycardia and Tachycardia Devices - Help Manual - June 2013 Art 60033180/A.

4.

Boston Scientific - Physician’s technical manual RESONATE™ HF ICD, RESONATE™ EL ICD, PERCIVA™ HF ICD, PERCIVA™ EL ICD, CHARISMA™ EL ICD, VIGILANT™ EL ICD, MOMENTUM™ EL ICD – Implantable Cardiovertor Defibrillator - 360204-001 EN Europe 2016-09. Physician’s technical manual RESONATE™ HF CRT-D, RESONATE™ CRT-D, RESONATE™ X4 CRT-D, CHARISMA™ CRT-D, CHARISMA™ X4 CRT-D, VIGILANT™ CRT-D, VIGILANT™ X4 CRT-D, MOMENTUM™ CRT-D, MOMENTUM™ CRT-D X4 – Cardiac Resynchronization Therapy Defibrillator 360203-001 EN Europe 2016-09.

5.

Functioning conditions for projected longevity (conditions based on Sorin data on file): SonR CRT-D models: Biventricular pacing in DDD mode, 30% in atrium, 100% in both ventricles, at 60min-1, 600Ω, A & RV pacing amplitude 2.5V, LV pacing amplitude 3V, 0.35ms, 3 max shocks per year, sensor OFF, SonR ON. CRT-D models: Biventricular pacing in DDD mode, 30% in atrium, 100% in both ventricles, at 60min-1, 600Ω, A & RV pacing amplitude 2.5V, LV pacing amplitude 3V, 0.35ms, 3 max shocks per year, sensor OFF. DR models: Pacing in SafeR mode, 30% in atrium, 6% in ventricle, at 60 min-1, 600Ω, 2.5V, 0.35ms, 4 max shocks per year, sensor OFF. VR models: Pacing in VVI mode 6% at 40min-1, 600Ω, 2.5V, 0.35ms, 4 max shocks per year, sensor OFF. Longevities are calculated by taking into account 6 months storage with the following conditions: Remote ON: daily check, 4 follow-ups and 5 full alert reports per year. RF telemetry ON: 45min for ICD / 120min for CRT-Ds at implant + 15min at discharge + 15min in-clinic quarterly FU.

6.

For more details please refer to the following document supplied with the device: U666 - LIMITED WARRANTY for PLATINIUM ICD & CRT-D devices.

7.

Under following conditions: SonR CRT-D models & CRT-D models: 100% atrial & biventricular pacing in DDD mode, 500Ω, with as-shipped settings, and deliver 11 shocks at 34J. DR models: 100% atrial & ventricular pacing in DDD mode, 500Ω, with as-shipped settings, and deliver 13 shocks at 34J. VR models: 100% pacing in VVI mode, 500Ω, with as-shipped settings, and deliver 15 shocks at 34J.

8.

Boriani G, Braunschweig F, Deharo JC et al. Impact of extending device longevity on the long-term costs of implantable cardioverter defibrillator therapy: a modelling study with a 15-year time horizon. Europace. 2013 Oct;15(10):1453-62.

We use cookies!

By continuing to browse the site you are agreeing to our use of cookies.

OK, I agree
OK, I agree